ECG Machine with Interpretation (three channel)

47,250.00

> WINGUARD
> Ecg Machine
> With Interpretation
> Three Channel
> Model ECG 32A II
> 14.4V 1200mAh
> 1 unit

* Lead
Standard 12 leads

* Input Circuit
Isolated input circuit;
Protection against defibrillation and pace making

* Data Acquisition: Simultaneously 12 lead acquisition

* Calibration Voltage: 1mV?5%

* Sampling Rate:1.25ms

* A/D Converter: 12 bit

* Filter: AC filter; EMG filter; DFT filter

* CMRR
> 60dB;
> 100dB ( with AC filter in use)

* Input Circuit Current
?0.1?A

* Input Impedance
>50M?

* Patient Leakage Current
< 100?A * Time Constant ?3.2s * Frequency Response 0.05 ~ 150Hz * Noise Level < 15?Vp-p * Paper Speed 6.25, 12.5, 25, 50mm/s * Sensitivity 2.5, 5, 10, 20mm/mV * Polarizing Voltage ?300mV * Baseline Control Automatic baseline control Automatic inhibition of baseline drift Note: * Do not directly contact together positive and negative poles of the battery. Otherwise, there will be the hazard of fire * Do not place the battery near a fire. Otherwise, there will be the hazard of explosion * Do not disassembly the battery without professional instructions. * The battery shall be a hazard with care and not be dropped

SKU: MHEM01 Category:

Description

> WINGUARD
> Ecg Machine
> With Interpretation
> Three Channel
> Model ECG 32A II
> 14.4V 1200mAh
> 1 unit

* Lead
Standard 12 leads

* Input Circuit
Isolated input circuit;
Protection against defibrillation and pace making

* Data Acquisition: Simultaneously 12 lead acquisition

* Calibration Voltage: 1mV?5%

* Sampling Rate:1.25ms

* A/D Converter: 12 bit

* Filter: AC filter; EMG filter; DFT filter

* CMRR
> 60dB;
> 100dB ( with AC filter in use)

* Input Circuit Current
?0.1?A

* Input Impedance
>50M?

* Patient Leakage Current
< 100?A * Time Constant ?3.2s * Frequency Response 0.05 ~ 150Hz * Noise Level < 15?Vp-p * Paper Speed 6.25, 12.5, 25, 50mm/s * Sensitivity 2.5, 5, 10, 20mm/mV * Polarizing Voltage ?300mV * Baseline Control Automatic baseline control Automatic inhibition of baseline drift Note: * Do not directly contact together positive and negative poles of the battery. Otherwise, there will be the hazard of fire * Do not place the battery near a fire. Otherwise, there will be the hazard of explosion * Do not disassembly the battery without professional instructions. * The battery shall be a hazard with care and not be dropped